OceanView Performance Data

 
Standard Glass Package
Thermal Performance
Northern Zone Glass Package
Thermal Performance
Air, Water & Structural
Performance
Sound Thermal Performance
Footnotes
Download
Performance PDF

Find the ENERGY STAR® climate zone for your location

Standard Glass Package Thermal Performance

  Visible Light
Transmittance2
   SHGC  
Glazing Window Style Total Unit U-Value1 Grids No
Grids
Daylight
Transmittance3
Tdw-ISO4 Grids No
Grids
Condensation
Resistance6

Low-e glass, low-conductance spacer
and argon gas fill.

Double-hung no grids 0.28  0.46  64% 0.462  0.20 58
Double-hung w/flat grids 0.28  0.40  64% 0.462 0.18 58
Double-hung w/deluxe grids 0.28  0.40 64% 0.462 0.18 58
Single-hung no grids 0.28  0.51  64% 0.462 0.20 58
Single-hung w/flat grids 0.28  0.40   64% 0.462 0.18  —  58
Single-hung w/deluxe grids 0.28  0.40  64% 0.462 0.18  —  58
Picture no grids 0.25  — 0.50   64%  0.443  — 0.22  62
Picture w/flat grids 0.25  0.44   64%  0.443 0.20  62
Picture w/deluxe grids 0.25  0.44   64% 0.443  0.20  —  62
Geometric no grids 0.24  —  0.53   64%  0.443 0.23  63
Geometric w/flat grids 0.24  0.57   64% 0.443 0.21  63
Geometric w/deluxe grids 0.24  0.57  —   64% 0.443 0.21  —  63
Casement no grids 0.27  —  0.41   64% 0.443  —  0.19  58
Casement w/flat grids 0.27  0.37  —   64%  0.443 0.17  —  58
Casement w/deluxe grids 0.27  0.37  —   64%  0.443 0.17  —  58
Casement Picture no grids 0.24  —  0.49   64% 0.443  0.21  58
Casement Picture w/flat grids 0.24  0.43  —   64% 0.443 0.19  —  58
Casement Picture w/deluxe grids 0.24  0.43  —   64% 0.443 0.19  —  58
Awning no grids 0.26  —  0.41   64% 0.443  —  0.19  57
Awning w/flat grids 0.26  0.37  —   64% 0.443 0.17  —  57
Awning w/deluxe grids 0.26  0.37  —   64% 0.443 0.17  —  57
2-lite slider no grids 0.28  —  0.45   64%  0.443  0.20  60
2-lite slider w/flat grids 0.28  0.40  —   64%  0.443 0.18  —  60
2-lite slider w/deluxe grids 0.28 0.40  —   64%  0.443 0.18  —  60
Patio Door no grids - Aluminum Sill 0.31  0.44   64%  0.443  0.19  52
Patio Door w/flat grids - Aluminum Sill 0.31  0.38   64%  0.443 0.17  —  52
Patio Door w/deluxe grids - Aluminum Sill 0.31 0.38  —   64%  0.443 0.17  —  52
Patio Door no grids - Vinyl Sill 0.30  0.44   64%  0.443  —  0.19  56
Patio Door w/flat grids - Vinyl Sill  0.30  0.38  —  64% 0.443  0.17  —  56
Patio Door w/deluxe grids - Vinyl Sill   0.30  0.38  —   64%  0.443  0.17  —  56
Transom / Sidelite  0.25  —  0.62   64%  0.443  —  0.32  63
Transom / Sidelite w/flat grids 0.25  0.56  —   64% 0.443 0.29  —  63
Transom / Sidelite w/deluxe grids 0.25  0.56  —   64%  0.443  0.29  63

 

 

Northern Zone Glass Package Thermal Performance

  Visible Light
Transmittance2
   SHGC  
Glazing Window Style Total Unit U-Value1 Grids No Grids Daylight
Transmittance3
Tdw-ISO4 Grids No Grids Condensation
Resistance6

Low-e glass,
low-conductance
spacer and
argon gas fill.

Double-hung no grids 0.28  0.51 71% 0.462  0.42 58
Double-hung w/flat grids 0.28  0.45 71% 0.462 0.37 58
Double-hung w/deluxe grids 0.28  0.45 71% 0.462 0.37 58
Single-hung no grids 0.29  0.50 71% 0.462 0.41 58
Single-hung w/flat grids 0.29  0.44 71% 0.462 0.37  —  58
Single-hung w/deluxe grids 0.29  0.44 71% 0.462 0.37  —  58
Picture no grids 0.26  — 0.55 71%  0.443  — 0.46  62
Picture w/flat grids 0.26  0.49 71%  0.443 0.41  62
Picture w/deluxe grids 0.26  0.49 71% 0.443 0.41  —  62
Geometric no grids 0.25  —  0.60 71%  0.443 0.31  63
Geometric w/flat grids 0.25  0.53 71% 0.443 0.28  63
Geometric w/deluxe grids 0.26  0.53  — 71% 0.443 0.28  —  63
Casement no grids 0.28  —  0.46 71% 0.443  —  0.38  58
Casement w/flat grids 0.28  0.42  — 71%  0.443 0.35  —  58
Casement w/deluxe grids 0.28  0.42  — 71%  0.443 0.35  —  58
Casement Picture no grids 0.25  —  0.55 71% 0.443  0.30  58
Casement Picture w/flat grids 0.25  0.49  — 71% 0.443 0.27  —  58
Casement Picture w/deluxe grids 0.26  0.49  — 71% 0.443 0.27  —  58
Awning no grids 0.28  —  0.46 71% 0.443  —  0.38  57
Awning w/flat grids 0.28  0.42  — 71% 0.443 0.35  —  57
Awning w/deluxe grids 0.28  0.42  — 71% 0.443 0.35  —  57
2-lite slider no grids 0.28  —  0.48 71%  0.443  0.40  60
2-lite slider w/flat grids 0.28 0.42  — 71%  0.443 0.35  —  60
2-lite slider w/deluxe grids 0.28 0.42  — 71%  0.443 0.35  —  60
Patio Door no grids - Aluminum Sill 0.32  0.49 71%  0.443  0.40  52
Patio Door w/flat grids - Aluminum Sill 0.32 0.42 71%  0.443 0.35  —  52
Patio Door w/deluxe grids - Aluminum Sill 0.32 0.42  — 71%  0.443 0.35  —  52
Patio Door no grids - Vinyl Sill 0.30  0.49 71%  0.443  —  0.40  56
Patio Door w/flat grids - Vinyl Sill 0.30  0.42  — 71% 0.443 0.35  —  56
Patio Door w/deluxe grids - Vinyl Sill 0.30  0.42  — 71%  0.443 0.35  —  56
Transom / Sidelite 0.25  —  0.62 71%  0.443  —  0.32  63
Transom / Sidelite w/flat grids 0.25  0.56  — 71% 0.443 0.29  —  63
Transom / Sidelite w/deluxe grids 0.25  0.56  — 71%  0.443  0.29  63

 

 

Air, Water and Structural Performance

Window Style Individual
Unit Size
Secondary
Unit Size
Total
Unit Size
Test Method
Total Unit
Air Infiltration
@25MPH
Water
(PSF)
Structural
Rating
Overall
Grade
Rating
Double-hung 48" x 80" ASTM E 1886-05 / ASTM E 1996-05 0.13 CFM 7.52 50 R50
Single-hung 48" x 80" ASTM E 1886-05 / ASTM E 1996-05 0.05 CFM 7.52 50 R50
Single-hung 52" x 80" ASTM E 1886-13/ ASTM E 1996-14 0.07 CFM 8.36 50 R50
Triple Single-hung 160" x 80" TBD ASTM E 1886-02 / ASTM E 1996-02  0.07 CFM 8.36 55 R55
Picture 72" x 72" ASTM E 1886-02 / ASTM E 1996-02  0.02 CFM 9.20  50 R50
Picture 96" x 48" ASTM E 1886-05 / ASTM E 1996-05 0.01 CFM 12.12 50 R50
Triple Picture 160" x 80" TBD ASTM E 1886-02 / ASTM E 1996-02 0.01 CFM 12.11 65 R65
Geometric 72" x 64" ASTM E 1886-02 / ASTM E 1996-02 0.02 CFM 12.11 50 R50
Geometric 72" x 72" ASTM E 1886-05 / ASTM E 1996-05 0.02 CFM 12.11 50 R50
Geometric 96"x48" ASTM E 1886-05 / ASTM E 1996-05 0.01 CFM 12.12 50 R50
Casement 36" x 72" ASTM E 1886-05 / ASTM E 1996-05 0.01 CFM 12.11 50  R50
Casement Picture 36" x 72"  — ASTM E 1886-05 / ASTM E 1996-05 0.01 CFM 12.11 50 R50
Awning  60" x 36"  — ASTM E 1886-05 / ASTM E 1996-05 0.01 CFM  12.11  50 R50 
2-Lite Slider 96" x 48"  — ASTM E 1886-05 / ASTM E 1996-05 0.10 CFM  9.20  50 R50 
2-Lite Slider 72" x 60"  — ASTM E 1886-05 / ASTM E 1996-05 0.14 CFM  7.52  50 R50 
2-Panel patio door - Aluminum Sill  96" x 96"  — ASTM E1886 / E1996-02 0.12 CFM  7.50  50  R50
2-Panel patio door - Vinyl Sill 96" x 96"  — AAMA 506-08 0.11 CFM  7.50  50 R50 
2-Panel door transom†  96" x 48"  — AAMA/WDMA/CSA 101/I.S.2/A440-05. 0.01 CFM  12.12  50 R50 
3-Panel patio door - Aluminum Sill* 144" x 96"  — ASTM E 1886 / E 1996-05  0.12 CFM  7.50  50 R50 
3-Panel patio door - Vinyl Sill* 144" x 96"  — ASTM E 1886 / E 1996-05  0.27 CFM  7.50  50 R50 
4-Panel patio door - Aluminum Sill* 192" x 96"  —  — ASTM E 1886 / E 1996-05 0.27 CFM 7.50 50 R50 
4-Panel patio door - Vinyl Sill* 192" x 96"  —  — ASTM E 1886 / E 1996-05 0.27 CFM 7.50 50 R50 
Sidelite  48" x 96"  —  AAMA 506-8  0.01 CFM  12.12 50  R50

†Overall size includes 1" per mullion per measurement.    

All patio doors are available as a KD 

*STOCK AND CUSTOM SIZED DOORS WITHIN THESE SIZES ARE KD ASSEMBLY ONLY

 

Sound Transmission

Window Style
Unit Size
IG Unit Glazing
STC  OITC
Double-Hung 47-1/4" x 59" 15/16" 1/8" tempered, 17/16" space, 3/32" SS clear / .090 clear PVB / 3/32" SS clear 34* 27*
Single-Hung 47-1/4" x 59" 15/16" 1/8" tempered, 9/16" space, 3/32" SS clear / .090 clear PVB / 3∕32" SS clear 34 27
Casement 23-1/2" x 59" 15/16" 1/8" tempered, 9/16" space, 3/32" SS clear / .090 clear PVB / 3∕32" SS clear 35 28
2-Lite Slide 59" x 47-1/4" 15/16" 1/8" annealed, 1/2" space, 1/8" annealed 28 23
Picture  47-1/4" x 59"  15/16" 1/8" tempered, 9/16" space, 3/32" SS clear / .1 clear PVB / 3∕32" SS clear 35  28
Geometric  59" x 47-1/4"  15/16" 1/8" tempered, 9/16" space, 3/32" SS clear / .1 clear PVB / 3∕32" SS clear  35  28
Patio Door 78-3/4" X 78-3/4" 1" 1/8" tempered, 5/8" space, 5/16" laminated  34 28
STC rating was calculated in accordance with ASTM E 413.

*DH numbers are based on actual test results. The balance of the sound transmission tests are not yet complete; the theoretical numbers listed are based on the glass packageand the style of window which are the determining factors of this test. Actual test results will be added when they become available. STC rating was calculated in accordance with ASTM E 413.
Modifications: none

 

 

 

 

 

 

 

 

 

 

 

 

OceanView Thermal Testing Footnotes
Window Style Size

Terms

Double-hung    47-1/4" x 59"

1 Windows tested per NFRC 100. Data applies to double-pane insulating glass units using double-strength glass and laminated double-strength glass with a
½" airspace. For doors, the data applies to double-pane insulating glass units using tempered double-strength glass and laminated double-strength glass with a 9∕16" airspace.

2 Tested using GED’s Intercept® ULTRA low-conductance warm-edge spacer system. Calculations provided by Lawrence Berkeley Laboratory Window 5.2 and Optics5 software based on a 15∕16" IG window unit and a 1" IG door unit.

3 Daylight transmittance measures the performance of the glass only.

4 International Standards Organization Damage Weighted Transmission
Rating (Tdw-ISO) calculations performed by Lawrence Berkeley Laboratory 5.2 Windows software and is weighted using recommended International
Commission on Illumination (CIE) standards.

5 Solar Heat Gain Coefficient (SHGC) tested in accordance with NFRC 200.
This value varies by style, glazing system and grids.

6 Condensation resistance is tested in accordance with NFRC 500.
Impact rating achieved for wind zone 3, missile level D.

Single-hung    47-1/4" x 59"
Picture    47-1/4" x 59"
Geometric   47-1/4" x 59"
Casement    23-5/8" x 59"
Awning  23-5/8" x 59"
Patio Door -Aluminum Sill  78-1/4" x 78-1/4"
Patio Door - Vinyl Sill    78-3/4" x 78-3/4"