Performance Data

Thermal Performance Air, Water & Structural Performance Glossary

Here's a sample of our complementary window styles and related thermal performance.

Thermal Performance 2-Lite Slider (Solarban 60*, Low-Conductance Spacer, Argon Gas Fill) 59x47-1/4 Hopper (Solarban 60, Low-Conductance Spacer, Argon Gas Fill) 49x36 Picture (Solarban 60, Low-Conductance Spacer, Argon Gas Fill) 47-1/4x59 Geometric (Solarban 60, Low-Conductance Spacer, Argon Gas Fill) 47-1/4x59
Total Unit U-Value1 0.29 0.31 0.27 0.26

Visible Light
Transmittance2
   Grids
   No Grids 

 

0.44
0.49

0.45
0.50
0.51
0.57 
0.49
0.55 
Daylight Transmittance3 72% 72%  72% 72%
Tdw-ISO4 0.559 0.568  0.559 0.559

SHGC5
   Grids
   No Grids 

0.24
0.27 
0.25
0.27 
0.28
0.31 
0.29
0.33 
Condensation Resistance6 59   60 61 61

1 Windows tested per NFRC 100. Data applies to double-pane insulated glass using a double-strength glass with 11/16" airspace.
2 Tested using GED's Intercept® ULTRA low-conductance warm-edge spacer system. Calculations provided by Lawrence Berkeley Laboratory Window 5.2 and Optics5 software based on 15/16" IG unit.
3 Daylight transmittance measures the performance of glass only.
4 International Standards Organization Damage Weighted Transmission Rating (Tdw-ISO) calculations performed by Lawrence Berkeley Laboratory 5.2 Windows software and is weighted using recommended International Commission on Illumination (CIE) standards.
5 Solar Heat Gain Coefficient (SHGC) tested in accordance with NFRC 200. This value varies by style, glazing system and grids.
6 Condensation resistance is tested in accordance with NFRC 500.

 

Here's a sample of our complementary window styles and related air, water and structural performance.

Air, Water & Structural Performance 2-Lite Slider 96x48 Hopper 49x36 Picture 72x84 Geometric  96x48
Overall Grade Rating R45 R25 R55 R70
Structural Rating 45 25 55 70
Water (PSF) 9.20 6.06 12.12 12.12
Total Unit Air Infiltration @ 25 mph 0.15 CFM 0.01 CFM 0.02 CFM 0.01 CFM
Test Method AAMA/WDMA/CSA 101/I.S.2/A440-05 AAMA/WDMA/CSA 101/I.S.2/A440-08 AAMA/WDMA/CSA 101/I.S.2/A440-05 AAMA/WDMA/CSA 101/I.S.2/A440-05

 

Glossary

Condensation Resistance Factor: Calculated from the interior surface temperature of a window when the window is subject to a standardized set of temperature and humidity conditions. The higher the number, the better the ability of the window to resist condensation. This AAMA test is voluntary with a minimum standard of 35 for thermally improved windows.

Daylight Transmittance: The measured amount of visible light transmitted through glass.

International Standards Organization Damage Weighted Transmission Rating (Tdw-ISO): Quantifies the ability of a glass package to reduce fading by measuring the effects of both ultraviolet and visible light.

Low-Emissivity (Low "E): Glass coated with a microscopically thin metallic layer that allows the short wave light energy to pass through as it blocks long wave ultraviolet and infrared solar energy by reflecting it back toward its source (toward the outside in summer and toward the inside in winter).

Outdoor-Indoor Transmission Class (OITC): Creates a single number rating for facade elements such as windows and doors that are subjected to transportation noises in the low to mid-frequency range of 80 to 4000 hertz. The higher the number, the better the noise isolation.

Overall Grade Rating: Code that designates style of window, recommended application and the window's performance grade which is also the window's design pressure in pounds per square foot.

Solar Heat Gain Coefficient (SHGC): Measures the amount of radiant heat transfer from the sun through a window. The lower the number means the less amount of solar heat transfer through the window (lower is better in the south).

Sound Transmission Class (STC): Provides a single number rating for interior building partitions subject to noises in the mid- to high frequency range of 125 to 4000 hertz. The higher the number, the better the noise isolation.

U-Value: The rate heat flows through a product for each degree of the temperature difference between one side and the other. The lower the U-value, the greater a window's resistance to heat flow and the better its insulating value.

Visible Light Transmittance: A relative amount of visible light transmitted through a fenestration product (including the frame which has no visible transmittance) with theoretical range from 1.00 to 0.00. The smaller the number, the less visible light is transmitted. The higher the number, the greater the contribution to daylighting potential.