Cambridge – Performance Data

Standard Glass Package Thermal Performance

For the North-Central, South-Central, and Southern Climate ENERGY STAR Zones

GlazingWindow StyleWindow SizeTotal Unit
U-Value1
Visible Light
Transmittance 2
SHGC 5Condensation
Resistance 6
ENERGY STAR
CERTIFICATION
GridsNo GridsGridsNo GridsYES NO
Low-e glass,
low-conductance
spacer and
argon gas fill.
Double-Hung<= 48" x 72"0.29 0.410.460.180.2058NO GRIDS GRIDS
Single-Hung<= 40" x 72" 0.290.410.460.180.2057Y_
PictureANY SIZE 0.260.450.510.200.2261Y_
Geometric ANY SIZE 0.250.480.540.210.2363Y_
Casement <= 36" x 72" 0.280.380.420.170.1860Y_
Casement Picture<= 72" x 72" 0.260.440.500.190.2160Y_
Awning<= 60" x 36" 0.290.380.420.170.1856Y_
Slider<= 96" x 60" 0.280.390.440.170.1961Y_
Vinyl Sill Patio Door<= 192" x 96" 0.310.390.450.170.2056_N
Transom /SidelitesANY SIZE0.500.500.560.220.2463Y_

Northern Zone Glass Package Thermal Performance

For the Northern Climate ENERGY STAR Zone

GlazingWindow StyleSizeTotal Unit
U-Value1
Visible Light
Transmittance 2
SHGC 5Condensation
Resistance 6
ENERGY STAR
CERTIFICATION
GridsNo GridsGridsNo GridsYES NO
Low-e glass,
low-conductance
spacer and
argon gas fill.
Double-Hung<= 48" x 72" 0.30 0.48 0.540.38 0.4357NO GRIDS GRIDS
Single-Hung<= 40" x 72" 0.30 0.480.540.380.4257NO GRIDS GRIDS
PictureANY SIZE 0.27 0.53 0.590.41 0.4561Y_
GeometricANY SIZE0.260.570.630.450.4963Y_
Casement<= 36" x 72"0.290.440.490.350.3859NO GRIDS GRIDS
Casement Picture<= 72" x 72"0.270.490.510.410.4660Y_
Awning<= 60" x 36"0.290.440.490.350.3956NO GRIDS GRIDS
Slider<= 96" x 60"0.290.460.520.360.4061NO GRIDS GRIDS
Vinyl Sill Patio Door<= 192" x 96"0.320.450.520.350.4056_N
Transom /Sidelites ANY SIZE0.270.590.660.460.5162Y_

Air, Water and Structural Performance

Window StyleIndividual
Unit Size
Mulled
Unit Size
***Test MethodTotal Unit
Air Infiltration
@25MPH
Water
(PSF)
Structural
Rating
Overall
Grade
Rating
Double-Hung48"x 72"_AAMA/WDMA/CSA 101/I.S.2/A440-050.11 CFM9.8260R60
Single-Hung48"x 72"_AAMA/WDMA/CSA 101/I.S.2/A440-050.09 CFM9.1960R36
Double-Hung Oriel36"x 72"_AAMA/WDMA/CSA 101/I.S.2/A440-050.06 CFM7.5250R50
Double-Hung Reverse Oriel48"x 72"_AAMA/WDMA/CSA 101/I.S.2/A440-05 0.11 CFM7.5250R50
Single-Hung Oriel 36"x 72"_AAMA/WDMA/CSA 101/I.S.2/A440-05 0.05 CFM7.5250R50
Single-Hung Reverse Oriel36"x 72"_AAMA/WDMA/CSA 101/I.S.2/A440-050.03 CFM6.0640R40
Twin Double-Hung 52" x 80"104" x 80"AAMA/WDMA/CSA 101/I.S.2/A440-050.11 CFM

7.5240R40
Triple Double-Hung52"x 80"157" x 80"AAMA/WDMA/CSA 101/I.S.2/A440-05 0.11 CFM7.5240R40
Picture96"x 48"_AAMA/WDMA/CSA 101/I.S.2/A440-050.01 CFM12.1270R70
2-Lite Slider96"x 48"_AAMA/WDMA/CSA 101/I.S.2/A440-05 0.10 CFM9.2050R50
3-Lite Slider 1/4-1/2-1/4138"x 60"_AAMA/WDMA/CSA 101/I.S.2/A440-05 0.08 CFM 8.3625R25
3-Lite Slider 1/3-1/3-1/3138"x 60"_AAMA/WDMA/CSA 101/I.S.2/A440-050.11 CFM 8.3630R30

Sound Transmission

Window StyleUnit SizeIG UnitGlazingSTC OITC
Double-Hung 47-1/4"x 59"15/16" 1/8" annealed, 1/2" spacer, 1/8" annealed 2722
Single-Hung47-1/4" x 59"15/16"1/8" annealed, 1/2" spacer, 1/8" annealed 2722
Picture 47-1/4"x 59"15/16" 1/8" annealed, 1/2" spacer, 1/8" annealed3125
2-Lite Slider 59"x 47-1/4"15/16" 1/8" annealed, 1/2" spacer, 1/8" annealed2722
STC rating was calculated in accordance with ASTM E 413.

Cambridge Thermal Testing Footnotes

1 Windows tested per NFRC 100. Data applies to double-pane insulated glass units using a double-strength glass with a 1/2″ airspace.

Data applies to: *Cambridge double-pane insulated glass units using double-strength glass with 11/16″ air space.

2 Tested using GED’s Intercept® ULTRA low-conductance warm-edge spacer system. Calculations provided by Lawrence Berkeley Laboratory Window 7.4 and Optics5 software based on 15/16″ IGU for Cambridge windows.

3 Daylight Transmittance measures the performance of the glass only.

4 International Standards Organization Damage Weighted Transmission Rating (Tdw-ISO) calculations performed by Lawrence Berkeley Laboratory 7.4 Windows software and is weighted using recommended International Commission on Illumination (CIE) standards.

5 Solar Heat Gain Coefficient (SHGC) tested in accordance with NFRC 200. This value varies by style, glazing system and grids.

6 Condensation Resistance is tested in accordance with NFRC 500.

Click on the link below to view the Cambridge Performance Data as a PDF and to download it to your own device.

Viwinco – Cambridge Performance Data