For the North-Central, South-Central, and Southern Climate ENERGY STAR Zones
Glazing | Window Style | Size | Total Unit U-Value1 | Visible Light Transmittance 2 | SHGC 5 | Condensation Resistance 6 | ENERGY STAR CERTIFICATION | |||||
Grids | No Grids | Grids | No Grids | YES | NO | |||||||
Low-e glass, low-conductance spacer and argon gas fill. | Double-Hung | <= 36" x 72" | 0.29 No Grids 0.31 With Grids | 0.42 | 0.48 | 0.19 | 0.21 | 58 | NO GRIDS | GRIDS | ||
2-Lite Slider | <= 108" x 48" | 0.28 | 0.44 | 0.49 | 0.19 | 0.21 | 60 | Y | - | |||
Hopper | <= 49" x 36" | 0.30 | 0.40 | 0.44 | 0.17 | 0.19 | 60 | Y | - | |||
Picture | <= 72" x 72" | 0.26 | 0.46 | 0.52 | 0.20 | 0.22 | 60 | Y | - |
For the Northern Climate ENERGY STAR Zone
Glazing | Window Style | Size | Total Unit U-Value1 | Visible Light Transmittance 2 | SHGC 5 | Condensation Resistance 6 | ENERGY STAR CERTIFICATION | |||||
Grids | No Grids | Grids | No Grids | YES | NO | |||||||
Low-e glass, low-conductance spacer and argon gas fill. | Double-Hung | <= 36" x 72" | 0.30 No Grids 0.31 With Grids | 0.49 | 0.55 | 0.38 | 0.43 | 58 | NO GRIDS | GRIDS | ||
2-Lite Slider | <= 108" x 48" | 0.29 | 0.51 | 0.58 | 0.40 | 0.45 | 59 | Y | - | |||
Hopper | <= 49" x 36" | 0.31 | 0.47 | 0.51 | 0.36 | 0.39 | 60 | - | N | |||
Picture | <= 72" x 72" | 0.28 | 0.54 | 0.60 | 0.42 | 0.47 | 59 | Y | - |
Window Style | Individual Unit Size | Mulled Unit Size | ***Test Method | Total Unit Air Infiltration @25MPH | Water (PSF) | Structural Rating | Overall Grade Rating | |
Double-Hung | 36"x 72" | _ | AAMA/WDMA/CSA 101/I.S.2/A440-11 | 0.12 CFM | 6.06 | 40 | R40 | |
Double-Hung | 48"x 80" | _ | AAMA/WDMA/CSA 101/I.S.2/A440-11 | 0.10 CFM | 5.43 | 30 | R30 | |
Double-Hung Oriel | 36"x 72" | _ | AAMA/WDMA/CSA 101/I.S.2/A440-11 | 0.13 CFM | 6.06 | 40 | R40 | |
Double-Hung Oriel | 48"x 80" | _ | AAMA/WDMA/CSA 101/I.S.2/A440-11 | 0.08 CFM | 6.06 | 35 | R35 | |
Double-Hung Reverse Oriel | 36"x 72" | _ | AAMA/WDMA/CSA 101/I.S.2/A440-11 | 0.15 CFM | 6.06 | 40 | R40 | |
Double-Hung Reverse Oriel | 48"x 80" | _ | AAMA/WDMA/CSA 101/I.S.2/A440-11 | 0.15 CFM | 6.06 | 30 | R30 | |
Triple Double-Hung | 48"x 80" | 145"x 80" | AAMA/WDMA/CSA 101/I.S.2/A440-11 | 0.10 CFM | 5.43 | 30 | R30 | |
Picture | 72"x 72" | _ | AAMA/WDMA/CSA 101/I.S.2/A440-08 | 0.01 CFM | 12.11 | 35 | R35 | |
Triple Picture Window | 48"x 72" | 144"x 72" | AAMA/WDMA/CSA 101/I.S.2/A440-08 | 0.01 CFM | 12.11 | 35 | R35 | |
Twin Picture Window | 48"x 72" | 96"x 112" | AAMA/WDMA/CSA 101/I.S.2/A440-08 | 0.01 CFM | 12.11 | 20 | R20 | |
Twin Picture Window with Transom | 96"x 40" | _ | ||||||
Edgemont 2-Lite Slider | 84"x 48" | _ | AAMA/WDMA/CSA 101/I.S.2/A440-08 | 0.06 CFM | 8.35 | 40 | R40 | |
Edgemont 2-Lite Slider | 84"x 36" | _ | AAMA/WDMA/CSA 101/I.S.2/A440-08 | 0.06 CFM | 8.35 | 35 | R35 | |
Edgemont 3-Lite Slider 1/4-1/2-1/4 | 108"x 48" | _ | AAMA/WDMA/CSA 101/I.S.2/A440-08 | 0.06 CFM | 6.06 | 35 | R35 | |
Edgemont 3-Lite Slider 1/3-1/3-1/3 | 108"x 48" | _ | AAMA/WDMA/CSA 101/I.S.2/A440-08 | 0.06 CFM | 7.52 | 35 | R35 | |
Edgemont Hopper | 49"x 36" | _ | AAMA/WDMA/CSA 101/I.S.2/A440-08 | 0.01 CFM | 6.06 | 25 | R25 |
Window Style | Unit Size | IG Unit | Glazing | STC | OITC | |
Double-Hung | 47-1/4"x 59" | 3/4" | 1/8" annealed, 1/2" spacer, 1/8" annealed | 28 | 23 | |
Picture | 47-1/4"x 59" | 3/4" | 1/8" annealed, 1/2" spacer, 1/8" annealed | 27 | 22 | |
2-Lite Slider | 59"x 47-1/4" | 3/4" | 1/8" annealed, 1/2" spacer, 1/8" annealed | 28 | 22 | |
STC rating was calculated in accordance with ASTM E 413. |
1 Windows tested per NFRC 100. Data applies to double-pane insulated glass units using a double-strength glass with a 1/2″ airspace.
Data applies to: *Edgemont double-pane insulated glass units using double-strength glass with 1/2″ air space.
2 Tested using GED’s Intercept® ULTRA low-conductance warm-edge spacer system. Calculations provided by Lawrence Berkeley Laboratory Window 7.4 and Optics5 software based on a 3/4″ IG unit for Edgemont windows.
3 Daylight Transmittance measures the performance of the glass only.
4 International Standards Organization Damage Weighted Transmission Rating (Tdw-ISO) calculations performed by Lawrence Berkeley Laboratory 7.4 Windows software and are weighted using the recommended International Commission on Illumination (CIE) standards.
5 Solar Heat Gain Coefficient (SHGC) tested in accordance with NFRC 200. This value varies by style, glazing system, and grids.
6 Condensation Resistance is tested in accordance with NFRC 500.
Click on the link below to view the Edgemont Performance Data as a PDF and to download it to your own device.